For business and partners
Offices, meeting rooms, networks and building systems. And for electricians, interior designers and developers — individual work stages and KNX programming.
For companies
Office Automation
Smart lighting, climate and security management for office spaces.
Meeting Rooms
Audio-video integration, lighting and climate control in meeting rooms.
Networks, Wi-Fi & Server Racks
Wi-Fi without dead zones, a separate network for the smart home, VPN access, assembled and labelled racks.
Engineering Systems Dispatching
Unified monitoring and management of all engineering systems.
For electricians, interior designers and developers
You can order the full cycle or just one stage: a design for your electrician, the control panel, or commissioning of a system that someone else installed.
Design
- Technical documentation and installation schematics
- Equipment specification with part numbers
- KNX group address plan / system integration map
- Documentation that lets us — or your local electrician — install everything
A complete set of schematics and specifications, ready to hand to any contractor
Panel Assembly
- Balkans: panel assembled and tested before we go to site
- Balkans: panel installed and connected on site
- EU projects: we supply the panel drawings; your panel builder or electrician assembles it
A labelled, tested panel — or a complete drawing set for local assembly
Programming & Commissioning
- Full system configuration: KNX programming, scenes, device setup
- Verification of every function
- Operation walkthrough for the owner
A fully configured, verified system with operating instructions
Supervision & Audit
- Checking another contractor's work against the design
- Technical supervision during third-party installation
- Finding faults and recommending fixes
An inspection report with findings and recommendations
Technical tasks
KNX Programming
Design and programming of systems based on the international KNX standard.
Connecting Equipment via Modbus, MQTT and API
Integration of industrial equipment, controllers and external services.
Tact Automation Hardware Programming
Programming our own Tact Automation platform for dispatching and automation.
If you already have a system
System Check and Restoration After Another Integrator
The integrator has disappeared, there’s no documentation and something doesn’t work — we’ll work it out, fix it and give you all the files.
Maintenance and Support
Backups, changes on request and site visits — so the system keeps working for years.
Do you work on projects regularly?
Tell us about your projects — we’ll agree on the format, timing and prices for ongoing work.
Get a Preliminary Estimate
Leave your contact details — the engineer will get in touch, clarify the task and give you an approximate cost. The consultation is free.
Where we work and what we do
The engineer lives in Belgrade. In the Balkans we take on the whole project; in the European Union, everything that can be done remotely.
Balkans
Full cycleSerbia, Montenegro and neighbouring countries
- Site visit and survey
- Design and estimate
- Control panel and network rack assembly
- Commissioning and handover on site
- Service with site visits
European Union
RemoteGermany, Austria and other EU countries
- Design and equipment specification
- KNX and controller programming
- Commissioning via remote access
- Support and changes after handover
Installation and connection on site are done by your electrician following our documentation.
Articles for engineers
ETS, group addresses, climate zones — breakdowns from real projects.
How to structure 2 000 KNX group addresses so they are still readable after four years
At 200 addresses the structure does not matter. At 2 000 it decides whether the project can be maintained at all — a real scheme from an 860 m² installation, with the full list published.
Read articleThe ETS 6 group address import format, explained
Nine columns, and the level of an entry is decided by which column carries the name. The format documented, the pitfalls listed, and a generator published under MIT.
Read articleOne project table, two systems: killing duplicate data entry
The same address gets typed into ETS, into the controller config, and into the handover documentation. A year later all three disagree and none of them is authoritative.
Read article